Troubleshooting guide
Nine checks, in the order a technician would actually do them. The first four are free and take about a minute each.
Do these before anything else. They account for a large share of no-heat calls, and every one of them costs nothing.
If the furnace starts after any of these, nothing is broken. You are done.
These are the next five, roughly in the order a technician checks them. The first two you can do yourself. The last three need someone with a meter and the right parts.
What the furnace does before it fails narrows things down faster than any other clue.
| What you see or hear | Most likely cause | Who fixes it |
|---|---|---|
| Nothing at all. No sound, no display. | Power switch off, tripped breaker, or blower door ajar | You |
| Thermostat says heat is on, furnace silent | Thermostat batteries or wiring, or the interlock switch | You, then a pro |
| Lights, runs a few seconds, shuts off, retries | Dirty flame sensor | Pro |
| Clicking and humming, but no flame | Failed hot surface ignitor | Pro |
| Blower runs constantly but the air is cold | Fan set to ON instead of AUTO, or no ignition | You, then a pro |
| Runs, then shuts down after ten to twenty minutes | Clogged filter tripping the high limit switch | You |
| Water pooling near the furnace base | Blocked condensate drain, float switch tripped | Pro |
| Starts fine when it is mild, not on cold nights | Marginal ignitor or gas pressure under load | Pro |
Most furnaces also flash a diagnostic code on a small LED behind the front panel. Many units have the code key printed on the inside of that panel. Reading it before you call saves the technician time, and often saves you money.
These are not troubleshooting steps. They are reasons to stop.
Beyond those, resetting a furnace repeatedly is worth avoiding. Lockouts exist to stop a unit running in a state that could damage it, and forcing repeated ignition attempts can turn an inexpensive part into an expensive one.
Three things come up locally that national troubleshooting articles will not mention.
The first cold week is when everything fails. Around here a furnace can sit unused from April to October. The failures were already there, and switching on in the first cold snap is simply when you discover them. Running your heat for fifteen minutes in early autumn, while it is still easy to book a technician, is the cheapest insurance available.
A lot of older East Bay housing stock has wall or floor furnaces. Much of Alameda, San Leandro and older parts of Oakland still runs gravity wall units rather than a central forced air system. Those have no blower door, no filter and often a standing pilot light instead of an electronic ignitor, so several checks above simply do not apply. If your heater is a grate in the floor or a panel in a hallway wall, the relevant question is usually whether the pilot is lit.
Replacement means permits. Alameda County jurisdictions require a permit for furnace replacement, and it exists for good reason: it forces an inspection of the venting and gas connections. Any contractor who suggests skipping it is telling you something useful about how they work.
FAQ
A lit thermostat only means the thermostat has power. It does not mean the furnace is receiving the call for heat. The usual causes are dead thermostat batteries that still light the screen, the furnace power switch being off, or the blower door not being fully closed, which opens a safety interlock and prevents the furnace from starting at all.
That pattern almost always points to a dirty flame sensor. The furnace lights correctly, but the sensor that proves a flame is present cannot read it through the residue, so the control board shuts the gas valve as a safety measure. It is an inexpensive repair, but it involves the burner assembly and should be done by a technician.
Yes. Switch it off at the furnace power switch, wait about thirty seconds, and switch it back on. Do this once. If the furnace locks out again, it is protecting itself from a fault that is still present, and repeated resets can turn a small failure into a larger one.
A well maintained gas furnace generally runs for fifteen to twenty years. Past that, repairs become more frequent and parts get harder to source. If your unit is in that range and needs a significant repair, it is worth pricing a replacement alongside the repair before deciding.
Short cycling is not usually dangerous in itself, but it is a symptom of something the furnace has detected and is reacting to. If it is accompanied by a gas smell, a carbon monoxide alarm, soot or scorching, stop using it and get outside before calling anyone.